ST-IRZ-SAPKSU testing machine

Purpose

Automation of the Drive controllers' testing process by the downhole electric motors to check compliance with technical specifications and the required operation algorithm during  acceptance testing.

System components

  • operator workstation
  • control cabinet
  • ARM-ST-02 application software
  • set of connecting cables and adapters for each type of controller

The installation provides acceptance testing of the following controllers:

  • KSU IRZ500, UKSU manufactured by IRZ TEK LLC
  • "Electon 8", "Electon 9.1", "Electon 10" produced by CJSC "Electon"
  • "Cascade-2-200", "Cascade NT", "Borets VD", "Argus" produced by LLC "PK Borets"
  • other controllers upon request of the customer

Main functions:

  • protection of KSU shutdown if the insulation resistance decreases
  • protection against KSU activation with a rotating rotor
  • measurement of KSU line voltage
  • measurement of KSU current, Cosφ and load factor
  • KSU performance test in automatic control mode
  • check of KSU electrical interlocks
  • saving data if KSU power supply fails;
    • connection of the surface readout unit of downhole monitoring system
    • exchange protocol for drive
    • editing directories of exchange protocols
    • monitoring of the current state of the electric submersible pump (ESP) drive
    • creating new parameters for the protocol
  • reading and writing values for KSU parameters
  • storing values in the KSU database
    • compiling reports
    • testing algorithms editor

Advantages

  • automation of the PLC testing process with recording the test protocol in the database
  • reducing the time for testing PLC
  • diminishing influence of the "human factor" during testing
  • reducing the number of personnel for testing
  • saving protocols in the database during the full life cycle of the PLC
  • testing new PLC software
  • setting reference currents, voltages

ARM-ST-02 software provides the following:

  • reading and storing of measurement results
  • recording test results
  • check the PLCs in manual and automatic mode
  • recording test results
  • storing history in a database
ParameterValue
Supply voltage ~220 V ±10%
Power consumption <2000 VA
Power outputs of the tested controllers:
— control range ~66…286  V
15…30  V
— number of outputs 3
Discrete output channels:
— type "dry contact"
— number 10
Discrete input channels:
— type «24V»
— number 20
Analogue input channels:
— type 0—10 V
0—20 mA
— number 10
Analogue output channels:
— type 0—10 V
0—20 mA
— number 5
Channel for setting reference values of 3-phase voltages and currents with a given shape for checking the measuring inputs of controllers:
— channel parameters 2…50 Hz
~20…254 V
0,05…12 А
— number 1
Turbine rotation setting channel:
— channel parameters 0…50 Hz
~0…5 В V 3-ph
— number 1
Insulation resistance value setting channel:
— rated value, kohm 51; 100; 300; 510; 1000; 2000; 4300; 7500; 9100
— nominal 0—5 V
— number 2
Interface channels:
— type RS-485
— number 4
— type RS-232
— number 3
— type CAN
— number 1
— controller communication protocols Modbus RTU, 7.35
Overall dimensions: 2600х1300х2200 mm