The product is designed for operation within MF / VHF train and maintenance communication networks on railway transport as a linear fixed dual-band simplex radio.
Key features
- interoperation with radio equipment used in the railway network
- built-in faults monitoring of radio modules
- sending status to integrated monitoting and administration network
- integration with IP-networks, analogue 2- or 4-wire dispatching lines
- remote control from consoles at a distance of up to 20 km via analogue dual-band links
- small dispatching radio operation mode
Modifications
| Designation |
Bands |
Backup power supply, V |
Number of consoles |
| MF |
VHF |
48 |
24 |
2 |
1 |
0 |
| RVS-1-20 |
+ |
+ |
+ |
|
+ |
|
|
| RVS-1-20/0001 |
+ |
|
+ |
|
+ |
|
|
| RVS-1-20/0002 |
+ |
|
+ |
|
|
+ |
|
| RVS-1-20/0003 |
|
+ |
+ |
|
+ |
|
|
| RVS-1-20/0004 |
|
+ |
+ |
|
|
+ |
|
| RVS-1-20/0005 |
+ |
+ |
+ |
|
|
+ |
|
| RVS-1-20/0006 |
+ |
+ |
+ |
|
|
|
+ |
| RVS-1-20/0007 |
+ |
|
+ |
|
|
|
+ |
| RVS-1-20/0008 |
|
+ |
+ |
|
|
|
+ |
| RVS-1-20/0010 |
+ |
+ |
|
+ |
+ |
|
|
| RVS-1-20/0011 |
+ |
|
|
+ |
+ |
|
|
| RVS-1-20/0012 |
+ |
|
|
+ |
|
+ |
|
| RVS-1-20/0013 |
|
+ |
|
+ |
+ |
|
|
| RVS-1-20/0014 |
|
+ |
|
+ |
|
+ |
|
| RVS-1-20/0015 |
+ |
+ |
|
+ |
|
+ |
|
| RVS-1-20/0016 |
+ |
+ |
|
+ |
|
|
+ |
| RVS-1-20/0017 |
+ |
|
|
+ |
|
|
+ |
| RVS-1-20/0018 |
|
+ |
|
+ |
|
|
+ |
| Parameter |
MF |
VHF |
| Frequency range |
2.130 and 2.150 MHz |
151.725—156.000 MHz |
| Channel spacing |
20 kHz |
25 kHz |
| Ouput power: |
| — rated |
12 ±2 W |
9 ±1 W |
| — reduced |
6 W |
1, 3, 5 W |
| Linear interface |
10/100 BASE-T (Ethernet) |
| Connection control protocol |
SIP |
| Voice protocol |
RTP with G.711 coding |
| Monitoring-management protocol |
SNMP |
| Main power supply |
220 (–33…+22) V |
| Backup power supply |
24 or 48 V |